Bit Error Rate Testing
(Or Frame Error Rate Testing)
Q Remove RF Channel from Service and Place in Test Mode
May be problematic for busy, operational systems
Need to verify consistent interpretation of the test bit sequence and value
of status bits to avoid baseline errors
Q Digital analyzer or Instrumented Radio Used for Drive Test
Consider any differences between analyzer or instrumented radios and
the radios which will be used
Q Collect Data
Configure for sufficient settling time prior to each measurement to
ensure valid BER tests
Traditional sampling rates (> 40 wavelengths) for measurements in fading
environments still apply
At normal speeds, the above sampling period will collect sufficient bit
samples to be statistically valid
Q Analyze Data
Use processes recommended in TSB-88 to segment and analyze test data